LC1D25FD 25A 11KW Контактор с бобина LC1D25FD 25A 11KW
Арт.№: КОНТАКТОР LC1D25FD 25A 11KW
Принтирай
1 от 1
Поставените снимки са с илюстративен характер. В действителност продуктът може да се отличава външно, като това не променя функционалността и характеристиките на изделието.
ППЦ:
лв.
лв.
130.00
лв.
Валидност на промоцията
до
Налично
Добави в любими
Твоите любими продукти Информация
Контактор с бобина LC1D25FD 25A 11KW Contactor LC1D25FD,110VDC. 25A.11 KW.1NO +1NC.
Teknisk data
Egenskap Varde
apparatserie TeSys d
produkt contactor
Enhets korta namn LC1D
contactor application motorstyrning
resistiv belastning
utilisation category AC-1
AC-3
Polbeskrivning 3P
pole contact composition 3 slutande
Ue <= 690 V AC 25...400 Hz for power circuit
<= 690 V DC for power circuit
[Ie] rated operational current 25 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
40 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
Motor effekt kW 11 kW at 380...400 V AC 50/60 Hz
15 kW at 500 V AC 50/60 Hz
15 kW at 660...690 V AC 50/60 Hz
5.5 kW at 220...230 V AC 50/60 Hz
11 kW at 415...440 V AC 50/60 Hz
motor power hp 2 hp at 115 V AC 50/60 Hz for 1 phase motors
3 hp at 230/240 V AC 50/60 Hz for 1 phase motors
5 hp at 200/208 V AC 50/60 Hz for 3 phases motors
7.5 hp at 230/240 V AC 50/60 Hz for 3 phases motors
15 hp at 460/480 V AC 50/60 Hz for 3 phases motors
20 hp at 575/600 V AC 50/60 Hz for 3 phases motors
control circuit type DC standard
Manoverkretsspanning 110 V DC
auxiliary contact composition 1 NO + 1 NC
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
overvoltage category III
[Ith] conventional free air thermal current 40 A at <= 60 °C for power circuit
10 A at <= 60 °C for signalling circuit
Irms rated making capacity 450 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
rated breaking capacity 450 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 120 A <= 40 °C 1 min power circuit
240 A <= 40 °C 10 s power circuit
380 A <= 40 °C 1 s power circuit
50 A <= 40 °C 10 min power circuit
100 A 1 s signalling circuit
120 A 500 ms signalling circuit
140 A 100 ms signalling circuit
Rekommenderad sakringsstorlek 40 A gG at <= 690 V coordination type 2 for power circuit
63 A gG at <= 690 V coordination type 1 for power circuit
10 A gG for signalling circuit conforming to IEC 60947-5-1
Genomsnittlig impedans 2 mOhm at 50 Hz - Ith 40 A for power circuit
[Ui] rated insulation voltage 600 V for power circuit certifications CSA
600 V for power circuit certifications UL
690 V for power circuit conforming to IEC 60947-4-1
690 V for signalling circuit conforming to IEC 60947-1
600 V for signalling circuit certifications CSA
600 V for signalling circuit certifications UL
Elektrisk livslangd 1.65 Mcycles 25 A AC-3 at Ue <= 440 V
1.4 Mcycles 40 A AC-1 at Ue <= 440 V
power dissipation per pole 3.2 W AC-1
1.25 W AC-3
Skyddsholje med
installation Platta
rail
produkt standard EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
CSA C22.2 n°14
certifiering BV
CCC
CSA
DNV
gL
GOST
RINA
UL
LROS
connections - terminals control circuit: screw clamp terminals 1 cable(s) 1...4 mm? - cable stiffness: flexible - without cable end
control circuit: screw clamp terminals 2 cable(s) 1...4 mm? - cable stiffness: flexible - without cable end
control circuit: screw clamp terminals 1 cable(s) 1...4 mm? - cable stiffness: flexible - with cable end
control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm? - cable stiffness: flexible - with cable end
control circuit: screw clamp terminals 1 cable(s) 1...4 mm? - cable stiffness: solid - without cable end
control circuit: screw clamp terminals 2 cable(s) 1...4 mm? - cable stiffness: solid - without cable end
power circuit: screw clamp terminals 1 cable(s) 2.5...10 mm? - cable stiffness: flexible - without cable end
power circuit: screw clamp terminals 2 cable(s) 2.5...10 mm? - cable stiffness: flexible - without cable end
power circuit: screw clamp terminals 1 cable(s) 1...10 mm? - cable stiffness: flexible - with cable end
power circuit: screw clamp terminals 2 cable(s) 1.5...6 mm? - cable stiffness: flexible - with cable end
power circuit: screw clamp terminals 1 cable(s) 1.5...10 mm? - cable stiffness: solid - without cable end
power circuit: screw clamp terminals 2 cable(s) 2.5...10 mm? - cable stiffness: solid - without cable end
tightening torque control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm
control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat O 6 mm
power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2
operating time 53.55...72.45 ms closing
16...24 ms opening
safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mekanisk livslangd 30 Mcycles cycles
Arbetsomrade 3600 cyc/h at <= 60 °C
coil technology built-in bidirectional peak limiting diode suppressor
begransning pa manoverspanning 0.1...0.25 Uc at 60 °C drop-out
0.7...1.25 Uc at 60 °C operational
tiskonstant 28 ms ms
inrush power in W 5.4 W at 20 °C
hold-in power consumption in W 5.4 W at 20 °C
Typ av hjalpkontakter type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
type mirror contact (1 NC) conforming to IEC 60947-4-1
signalling circuit frequency 25...400 Hz
minsta brytstrom 5 mA for signalling circuit
minimum switching voltage 17 V for signalling circuit
non-overlap time 1.5 ms on de-energisation (between NC and NO contact)
1.5 ms on energisation (between NC and NO contact)
insulation resistance > 10 MOhm for signalling circuit
IP klass IP2x front face conforming to IEC 60529
protective treatment TH conforming to IEC 60068-2-30
Nedsmutsningsgrad 3
temperaturomrade -5...60 °C °C
ambient air temperature for storage -60...80 °C °C
tillaten omgivningstemperatur runt enheten -40...70 °C at Uc
operating altitude 3000 m without derating in temperature
fire resistance 850 °C conforming to IEC 60695-2-1
flame retardance V1 conforming to UL 94
mechanical robustness vibrations contactor open 2 Gn, 5...300 Hz
vibrations contactor closed 4 Gn, 5...300 Hz
shocks contactor closed 15 Gn for 11 ms
shocks contactor open 8 Gn for 11 ms
hojd 85 mm mm
bredd 45 mm mm
djup 101 mm mm
vikt 0.53 kg kg
Teknisk data
Egenskap Varde
apparatserie TeSys d
produkt contactor
Enhets korta namn LC1D
contactor application motorstyrning
resistiv belastning
utilisation category AC-1
AC-3
Polbeskrivning 3P
pole contact composition 3 slutande
Ue <= 690 V AC 25...400 Hz for power circuit
<= 690 V DC for power circuit
[Ie] rated operational current 25 A (<= 60 °C) at <= 440 V AC AC-3 for power circuit
40 A (<= 60 °C) at <= 440 V AC AC-1 for power circuit
Motor effekt kW 11 kW at 380...400 V AC 50/60 Hz
15 kW at 500 V AC 50/60 Hz
15 kW at 660...690 V AC 50/60 Hz
5.5 kW at 220...230 V AC 50/60 Hz
11 kW at 415...440 V AC 50/60 Hz
motor power hp 2 hp at 115 V AC 50/60 Hz for 1 phase motors
3 hp at 230/240 V AC 50/60 Hz for 1 phase motors
5 hp at 200/208 V AC 50/60 Hz for 3 phases motors
7.5 hp at 230/240 V AC 50/60 Hz for 3 phases motors
15 hp at 460/480 V AC 50/60 Hz for 3 phases motors
20 hp at 575/600 V AC 50/60 Hz for 3 phases motors
control circuit type DC standard
Manoverkretsspanning 110 V DC
auxiliary contact composition 1 NO + 1 NC
[Uimp] rated impulse withstand voltage 6 kV conforming to IEC 60947
overvoltage category III
[Ith] conventional free air thermal current 40 A at <= 60 °C for power circuit
10 A at <= 60 °C for signalling circuit
Irms rated making capacity 450 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
rated breaking capacity 450 A at 440 V for power circuit conforming to IEC 60947
[Icw] rated short-time withstand current 120 A <= 40 °C 1 min power circuit
240 A <= 40 °C 10 s power circuit
380 A <= 40 °C 1 s power circuit
50 A <= 40 °C 10 min power circuit
100 A 1 s signalling circuit
120 A 500 ms signalling circuit
140 A 100 ms signalling circuit
Rekommenderad sakringsstorlek 40 A gG at <= 690 V coordination type 2 for power circuit
63 A gG at <= 690 V coordination type 1 for power circuit
10 A gG for signalling circuit conforming to IEC 60947-5-1
Genomsnittlig impedans 2 mOhm at 50 Hz - Ith 40 A for power circuit
[Ui] rated insulation voltage 600 V for power circuit certifications CSA
600 V for power circuit certifications UL
690 V for power circuit conforming to IEC 60947-4-1
690 V for signalling circuit conforming to IEC 60947-1
600 V for signalling circuit certifications CSA
600 V for signalling circuit certifications UL
Elektrisk livslangd 1.65 Mcycles 25 A AC-3 at Ue <= 440 V
1.4 Mcycles 40 A AC-1 at Ue <= 440 V
power dissipation per pole 3.2 W AC-1
1.25 W AC-3
Skyddsholje med
installation Platta
rail
produkt standard EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 508
CSA C22.2 n°14
certifiering BV
CCC
CSA
DNV
gL
GOST
RINA
UL
LROS
connections - terminals control circuit: screw clamp terminals 1 cable(s) 1...4 mm? - cable stiffness: flexible - without cable end
control circuit: screw clamp terminals 2 cable(s) 1...4 mm? - cable stiffness: flexible - without cable end
control circuit: screw clamp terminals 1 cable(s) 1...4 mm? - cable stiffness: flexible - with cable end
control circuit: screw clamp terminals 2 cable(s) 1...2.5 mm? - cable stiffness: flexible - with cable end
control circuit: screw clamp terminals 1 cable(s) 1...4 mm? - cable stiffness: solid - without cable end
control circuit: screw clamp terminals 2 cable(s) 1...4 mm? - cable stiffness: solid - without cable end
power circuit: screw clamp terminals 1 cable(s) 2.5...10 mm? - cable stiffness: flexible - without cable end
power circuit: screw clamp terminals 2 cable(s) 2.5...10 mm? - cable stiffness: flexible - without cable end
power circuit: screw clamp terminals 1 cable(s) 1...10 mm? - cable stiffness: flexible - with cable end
power circuit: screw clamp terminals 2 cable(s) 1.5...6 mm? - cable stiffness: flexible - with cable end
power circuit: screw clamp terminals 1 cable(s) 1.5...10 mm? - cable stiffness: solid - without cable end
power circuit: screw clamp terminals 2 cable(s) 2.5...10 mm? - cable stiffness: solid - without cable end
tightening torque control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat O 6 mm
control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver flat O 6 mm
power circuit: 2.5 N.m - on screw clamp terminals - with screwdriver Philips No 2
operating time 53.55...72.45 ms closing
16...24 ms opening
safety reliability level B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Mekanisk livslangd 30 Mcycles cycles
Arbetsomrade 3600 cyc/h at <= 60 °C
coil technology built-in bidirectional peak limiting diode suppressor
begransning pa manoverspanning 0.1...0.25 Uc at 60 °C drop-out
0.7...1.25 Uc at 60 °C operational
tiskonstant 28 ms ms
inrush power in W 5.4 W at 20 °C
hold-in power consumption in W 5.4 W at 20 °C
Typ av hjalpkontakter type mechanically linked (1 NO + 1 NC) conforming to IEC 60947-5-1
type mirror contact (1 NC) conforming to IEC 60947-4-1
signalling circuit frequency 25...400 Hz
minsta brytstrom 5 mA for signalling circuit
minimum switching voltage 17 V for signalling circuit
non-overlap time 1.5 ms on de-energisation (between NC and NO contact)
1.5 ms on energisation (between NC and NO contact)
insulation resistance > 10 MOhm for signalling circuit
IP klass IP2x front face conforming to IEC 60529
protective treatment TH conforming to IEC 60068-2-30
Nedsmutsningsgrad 3
temperaturomrade -5...60 °C °C
ambient air temperature for storage -60...80 °C °C
tillaten omgivningstemperatur runt enheten -40...70 °C at Uc
operating altitude 3000 m without derating in temperature
fire resistance 850 °C conforming to IEC 60695-2-1
flame retardance V1 conforming to UL 94
mechanical robustness vibrations contactor open 2 Gn, 5...300 Hz
vibrations contactor closed 4 Gn, 5...300 Hz
shocks contactor closed 15 Gn for 11 ms
shocks contactor open 8 Gn for 11 ms
hojd 85 mm mm
bredd 45 mm mm
djup 101 mm mm
vikt 0.53 kg kg